INFICON Ecotec 4000 (Multi‑Gas Leak Detector/ Máy dò tìm rò rỉ (Máy phát hiện rò rỉ) đa khí)

Giá bán: Liên Hệ.

  • Mô tả sản phẩm

INFICON Ecotec® 4000

“High‑flow, highly selective leak detection for HVACR and automotive manufacturing”

 

End-of-line leak testing directly impacts profitability, compliance, and brand reputation.

In HVACR and automotive manufacturing, even small leaks can lead to costly rework, warranty claims, regulatory penalties, and lost customer trust.

In AI data centers, leaks in cooling systems directly threaten uptime, energy efficiency, and operational continuity—putting mission-critical infrastructure and service-level agreements at risk.

 

Ecotec 4000 enables manufacturers to turn leak testing into a predictable, high-performance production process.

It helps reduce total cost of ownership by minimizing leaks, stabilizing production, and increasing throughput—even under rising regulatory and efficiency pressures.

The Ecotec 4000 is designed for high-volume, automated manufacturing environments. By combining high-flow multi-gas detection with seamless automation and system integration, it delivers higher uptime, lower operational risk, and long-term process reliability across refrigeration, air conditioning, heat pump, and automotive applications—backed by INFICON, a trusted global partner.

Advantages

  • Most sensitive and selective multi-gas detection (down to 0.03 g/a R600a)
  • Adaptive multi‑flow technology:
    – Precision Mode (≈160 sccm): Maximum sensitivity
    – Optimum Mode (≈300 sccm): Balances short cycle times with high sensitivity (<0.2 g/a)
    – High‑Speed Mode (up to 3000 sccm): Highest speed for less demanding leak detection at medium detection limit (<2.0 g/a).
  • Smart Background Canceling: Minimizes false alarms by suppressing CO2 and other refrigerant interferences in high-background environments
  • Advanced IGS: Interfering Gas Suppression eliminates signals from blowing agents like cyclopentane or isopentane for R600a; now also usable for R290
  • Seamless robotics integration
  • Intuitive user interface and improved iGuide operator guidance simplify leak test operation, even for less experienced users
  • Modern Interfaces such as Ethernet, HDMI, USB, BM1000, and IO1000

Faster Detection. Smarter Integration. Lower Costs.

The Ecotec® 4000 detects up to four refrigerants simultaneously with sensitivity down to 0.03 g/a R600a, exceeding current industry standards. Built for automated production lines, its 180°-adjustable sniffer line connection and rear-panel interface layout enable direct integration into robotic leak-testing systems — no line modifications required. With a 7″ color touchscreen and simplified menu structure, operators have clear control at every step, with immediate access to all functions. Ethernet, HDMI, USB, BM1000, and IO1000 interfaces connect the device to existing networks and control systems. Improved core components maximize uptime, and a new standby mode cuts energy consumption by up to 40% — reducing operating costs while maintaining full production readiness.

Typical Applications

  • HVACR Industry: Final leak testing of refrigerators, freezers, heat exchangers, air conditioners, heat pumps, and data center cooling equipment
  • Automotive Industry: Leak testing of A/C systems, fuel rails (ICE), gas engines (LNG/CNG), battery and fuel-cell cooling circuits

Why Choose Ecotec 4000?

Compared with its predecessor and other sniffer detectors, the Ecotec 4000 delivers highest sensitivity, faster cycle times, and fewer false positives, all while integrating seamlessly into both manual and fully automated testing environments. Its robust design ensures consistent uptime, lower operational costs, and alignment with evolving regulatory and environmental requirements.

Specifications

Min. detectable leak rate at Precision Mode (160 sccm) for
Helium1 x 10-6 mbar·l/s
R600a0.03 g/a (0.001 oz./yr)
Min. detectable leak rate at Optimum Mode (300 sccm) for
Helium2 x 10-6 mbar·l/s
R600a0.2 g/a (0.007 oz./yr)
Min. detectable leak rate at High Speed Mode (2200–3000 sccm) for
Helium2 x 10-5 mbar·l/s
R600a2.0 g/a (0.07 oz./yr)
Measurement range0.05–999.99 g/a (0.002–99.999 oz./yr)
Response time of the sensor0.1 s
Response time incl. sniffer line3 m: 0.3 s; 5 m: 0.6 s; 10 m: 1.4 s; 15 m: 2.6 s
Max No. of gases detected
simultaneously
4
Leak rate unitsg/a; oz./yr; mbar·l/s; Pa m3/s; ppm
Time until operational readiness< 2 min
Dimensions (W x H x D)615 x 420 x 270 mm (24.2 x 16.5 x 10.6 in.)
Weight26.5 kg (58.4 lb.)
Gas flow through capillary130–170 ml/min (Precision Mode); 280–350 ml/min (Optimum Mode); 2200–3000 ml/min (High Speed Mode)
Permissible ambient temperature (in operation)10–45°C (50–113°F)

Ordering Information

Part Number

530-201Ecotec 4000 Multigas Leak detector 100–240 V ±10%, 50/60 Hz

Accessories

Sniffer lines
526-001SL4000 BC, 3 m length**
526-002SL4000 BC, 5 m length**
526-003SL4000 BC, 10 m length**
526-004SL4000 BC, 15 m length**
527-001SL4000, 3m length ***
527-002SL4000, 5 m length ***
527-003SL4000, 10 m length ***
527-004SL4000, 15 m length ***
527-005Roboter SL4000, 3 m length***
527-006Roboter SL4000, 5 m length***
527-007Roboter SL4000, 10 m length***
527-008Roboter SL4000, 15 m length***
**with background canceling function
***without background canceling function
Sniffer tips
528-001FT125, 125 mm, flexible
528-002FT250, 250 mm, flexible
528-003FT390, 390 mm, flexible
528-004FT600, 600 mm, flexible
528-005ST125, 125 mm, rigid
528-006ST250, 250 mm, rigid
528-007ST390, 390 mm, rigid
Sniffer tip attachments
531-040I-Tip Sense big pack
531-041I-Tip Sense small pack
531-041I-Tip Rugged big pack
531-033Attachement SL4000 plug-in connector****
531-035Attachment SL4000 water protection tip
****necessary for I-Tip
Additional accessories for sniffer line
531-012Holder for SL4000/SL4000 BC sniffer line
BUS and I/O modules
560-315BM1000 PROFIBUS
560-316BM1000 PROFINET
560-317BM1000 DeviceNet
560-318BM1000 EtherNet / IP
560-310IO1000 Module
560-334Data cable (IO1000 / BM1000) 0.5 m
560-335Data cable (IO1000 / BM1000) 5 m
560-340Data cable (IO1000 / BM1000) 10 m
Calibrated leak accessories
520-300CalMate 4000 calibrated leak adapter
520-310CalMate 4000 connection cable (1.5 m)

Consumables

Part NumberDescription
531-003IGS calibration kit
531-006EcoCheck 4000 calibration leak, R1234yf*
531-011Gas cartridge EcoCheck 4000, R1234yf
12220Refrigerant calibration leak R134a, 2–5 g/a
12221Refrigerant calibration leak R600a, 2–5 g/a
12222Refrigerant calibration leak R404a, 2–5 g/a
12227Refrigerant calibration leak R152a, 2–5 g/a
12228Refrigerant calibration leak R407c, 2–5 g/a
12229Refrigerant calibration leak R410a, 2–5 g/a
12231Refrigerant calibration leak R290, 7–8 g/a
12232Refrigerant calibration  leak CO2, 2–3.5 g/a
12235Refrigerant calibration leak R1234yf, 2–5 g/a
12240Refrigerant calibration leak R134a, 10–12 g/a
12241Refrigerant calibration leak R600a, 15–18 g/a
12275Refrigerant calibration leak R744 (CO2), 10–14 g/a
12301Refrigerant calibration leak R1234ze, 2–5 g/a
12305Refrigerant calibration leak R452A, 2–5 g/a
12320Refrigerant calibration leak R452B, 2–5 g/a
12324Refrigerant calibration leak R513A, 2–5 g/a
12323Refrigerant calibration leak R454B, 2–5 g/a
12321Refrigerant calibration leak R454C, 2–5 g/a
*optional, not included with Ecotec