Thiết bị hiệu chuẩn rò rỉ gas lạnh Calibration Leaks for Refrigerant Sniffer Leak Detectors
Giá bán: Liên Hệ.
- Mô tả sản phẩm
Calibration Leaks for Refrigerant Sniffer Leak Detectors – The Easy Way to Test and to Calibrate – For Maximum Accuracy
INFICON calibrated test leaks enable to test and to calibrate refrigerant sniffer leak detectors for the highest quality demands in leak detection. The handling of the test leaks and the calibration of the sniffer leak detectors is very easy. The function of these leaks is based on a special quartz capillary which is customized to deliver a specific reduced flow from a test gas reservoir.
INFICON provides a wide range of calibrated test leaks for refrigerant sniffer leak detectors in industrial enviroments. The test leaks are available in different leak rates and test gases.
Advantages
- Easy to use
- Suitable for industrial applications
- Available in different leak rates
- Inspection certificate included in accordance to DIN EN 10204:2004-3.1
- Traceable to PTB certificate
- Highly accurate and reliable due to the profil of the quartz capillary
- Metal-free capillary for low temperature dependance
- Refillable
Typical Applications
- Test and calibration of sniffer leak detectors
Part Number
12232 | Refrigerant Test Leak CO2, 2-3.5g/a |
12220 | Refrigerant Test Leak R134a, 2-5g/a |
12221 | Refrigerant Test Leak R600a, 2-5g/a |
12222 | Refrigerant Test Leak R404a, 2-5g/a |
12227 | Refrigerant Test Leak R152a, 2-5g/a |
12228 | Refrigerant Test Leak R407c, 2-5g/a |
12229 | Refrigerant Test Leak R410a,2-5g/a |
12235 | Refrigerant Test Leak R-1234 YF, 2-5 g/a |
12236S | Refrigerant Test Leak R32 2-8g/a |
12231 | Refrigerant Test Leak R290,7-8g/a |
12240 | Refrigerant Test Leak R134a,10-12g/a |
12241 | Refrigerant Test Leak R600a,15-18g/a |
12242 | Refrigerant Test Leak R404a,14-17g/a |
12275 | Refrigerant Test Leak R744 (CO2), 10-14g/a |
12300 | Refrigerant Test Leak SF6, 2-5 g/a |
12301 | Refrigerant Test Leak R1234ze, 2-5 g/a |
12304 | Refrigerant Test Leak R-245fa, 2-5g/a |
12305 | Refrigerant Test Leak R452A, 2-5 g/a |
12311 | Refrigerant Test Leak R-448A, 2-5g/a |
12320 | Refrigerant Test Leak R-452B, 2-5 g/a |
12321 | Refrigerant Test Leak R454C, 2-5 g/a |
12323 | Refrigerant Testleak R-454b, 2-5 g/a |
12324 | Refrigerant Test Leak R513A, 2-5g/a |
12327 | Refrigerant Test Leak R450A, 2-5 g/a |
12328 | Refrigerant Test Leak R438A, 2-5g/a |
Calibration Leak with Checkport for Refrigerant Sniffer Leak Detector – The Easy Way to Test and to Calibrate – For Maximum Accuracy
INFICON calibrated test leaks enable to test and to calibrate refrigerant sniffer leak detectors for the highest quality demands in leak detection. The handling of the test leaks and the calibration of the sniffer leak detectors is very easy. The function of these leaks is based on a special quartz capillary which is customized to deliver a specific reduced flow from a test gas reservoir.
INFICON provides a wide range of calibrated test leaks for refrigerant sniffer leak detectors in industrial enviroments. The test leaks are available in different leak rates and test gases.
Advantages
- Suitable for industrial applications
- Easy to use
- Available in different leak rates
- Inspection certificate included in accordance to DIN EN 10204:2004-3.1
- Traceable to PTB certificate
- Highly accurate and reliable due to the profil of the quartz capillary
- Metal-free capillary for low temperature dependance
- Refillable
Part Number
12329 | Refrigerant Testleak R600a, 0,5-0,8 g/a (Checkport) |